fbpx TRANSITION™ Pavers | Unilock New York
EN

TRANSITION

Enduracolor technology brings a refined surface and long-lasting color to the basic shapes of Transition™. Available in a wide variety of subtle color blends, Transition is an economical choice for driveways, patios and walkways. Combining the small rectangle and square can achieve a more random look, or the units can be used individually to create a simpler pattern.

Transition 230x150x60 Fossil
-
Transition 230x150x60 Fossil
-

TRANSITION

Enduracolor technology brings a refined surface and long-lasting color to the basic shapes of Transition™. Available in a wide variety of subtle color blends, Transition is an economical choice for driveways, patios and walkways. Combining the small rectangle and square can achieve a more random look, or the units can be used individually to create a simpler pattern.

Colors
Applications
Borders and Accents
Driveway
Heavy Duty Vechicular
Patio & Walkway
Shape and size
img
RECTANGLE
150mm x 230mm x 60mm
5 7/8" x 9" x 2 3/8"
img
RECTANGLE
150mm x 230mm x 60mm
5 7/8" x 9" x 2 3/8"
img
RECTANGLE
150mm x 230mm x 60mm
5 7/8" x 9" x 2 3/8"
img
RECTANGLE
150mm x 230mm x 60mm
5 7/8" x 9" x 2 3/8"
img
RECTANGLE
150mm x 230mm x 60mm
5 7/8" x 9" x 2 3/8"
img
RECTANGLE
150mm x 230mm x 60mm
5 7/8" x 9" x 2 3/8"

Product Gallery

Transition Driveways Almond Grove 1128
Transition Driveways Almond Grove 5442
Transition Driveways New York Blend 0520
Technologies
Technologies
EnduraColor
img
img

The refined surface of Unilock EnduraColor products is achieved with a two step manufacturing process that combines a base of coarser aggregates for a stronger foundation, with concentrated color and wear-resistant finer aggregates on top. This process protects the surface from the appearance of fading over time because the top layer prevents large, lighter color aggregates from ever showing through.

Our technologies
Colors
FOSSIL
STEEL MOUNTAIN
WALNUT
SIERRA
DARK CHARCOAL
ALMOND GROVE
Pick a color
FOSSIL
STEEL MOUNTAIN
WALNUT
SIERRA
DARK CHARCOAL
ALMOND GROVE
img
Information
Information
Packaging
Downloads

TRANSITION

 

For those looking for a smaller format paver that has the same randomness as Beacon Hill Flagstone, Transition Paver delivers that same look and feel at a smaller scale.

Recommended Base Stabilization – one layer of DriveGrid™" stabilization grid between subgrade and base material. Recommended depth 8” to 10” below pavers for maximum stability and performance. Use under Standard Base or Permeable Base.

Standard Base – Min. 6” – 8” of ¾” Crusher Run gravel (any road base standard in accordance with ASTM-D2940) compacted to 98% Standard Proctor Density (SPD).

Standard Bedding Course – 1” thick of coarse sand– in accordance with ASTM-D2940 screeded over base.

Alternative Permeable Base – Min. 6” – 8” of ¾“ clear open-graded stone compacted to achieve full particle lock-up and consolidation. (Clear open-graded does not compact but does consolidate slightly by rattling the particles together.)

Alternative Permeable Bedding Course – 1” thick of 1/4” clear open-graded chip stone – (ASTM No. 8) screeded over base.

Special Note: Concrete Direct Overlay – In some areas of the country and in some applications pavers are very successfully placed directly over concrete.  Concrete as a base is in itself quite strong, but it can affect the structural integrity of the paver particularly in vehicular applications, where the concrete below is sub-par. The following considerations must be taken into account to insure that the concrete below the surface is ideal:

  1. Concrete integrity – concrete must be in good condition, and not crumbling
  2. Drainage slope – concrete below must be sloped away from all buildings and structures
  3. Drainage holes – In lowest areas of the concrete, drill 1” holes in concrete (on 12” centers) and fill holes with ¼” chip (ASTM No. 8)
  4. Base drainage - the area below the concrete must not be subject to frost movement
  5. Surface - surface must be totally smooth and flat equivalent to the desired finished surface
  6. Waterproofing - may be required when installing pavers over concrete where there is a basement or cold cellar below. Install an impervious rubber membrane over the surface prior to installing any pavers over the surface.
  7. Jointing Sand -  Use an impervious polymeric sand when installing over concrete

Jointing Material and Joint Stabilization 

All sands must meet ASTM C144 or C33 Specifications. For best appearance and optimal performance,, keep jointing materials approximately 1/8” below the chamfer (bevel edge) of the paver.

Good Option: Ordinary sharp jointing sand in accordance with ASTM C144 or C33. (Common name: Concrete Sand)

Best Option: Any polymeric sand or ordinary concrete sand stabilized by a water-based or solvent-based joint sand stabilizer sealer. Always follow manufacturer’s application specifications and requirements.

              

Handling – Do not knock units together while transporting or installing. Doing so could chip edges or corners.

Edge Restraint - Always install an edge restraint around the perimeter of any paver installation not restrained by building structures. Spike-in edge restraints come in plastic and metal and work well for most applications. A concrete curb or a sub-surface concrete wedge can also be installed to retain the edge.

Paver Compaction - Always use a protective polymer pad on the bottom of your compactor when doing the final compaction of the pavers. An alternative is to use a rubber-roller compactor for the final compaction.

Cleaners – Any cleaner specifically designed for pavers may be used for color restoration or general cleaning. Follow manufacturer’s dilution rates and application procedures. Always test a small area to make sure the results are as expected.

 Sealers 

  • Product may be sealed for aesthetic or cleanliness reasons but it is not required
  • Use any sealer approved for concrete pavers
  • Selecttype for desired aesthetics
  • Productmust be cleaned before sealing
  • Always read and follow manufacturer’s application procedures
  • Always test a small area to make sure the results are as expected

 

The Americans with Disabilities Act Accessibility Guidelines (ADAAG) provides measurable criteria to determine compliance, not individual product evaluation. Gaps, joints or openings, greater than ½” horizontal and ¼” vertical should be avoided as they can disrupt wheelchair maneuvering (United States Access Board – Guidelines and Standards).

Unit Thickness (mm)
Layers per Bundle
Sq Ft per Bundle
Sq Ft per Layer
Sq Ft per Unit
Units per Bundle
Units per Layer
Lin Ft per Bundle - Soldier
Lin Ft per Layer - Soldier
Lin Ft per Unit - Soldier
Lin Ft per Bundle - Sailor
Lin Ft per Layer - Sailor
Lin Ft per Unit - Sailor
Lbs per Bundle
Lbs per Layer
Lbs per Unit
RECTANGLE
60
10
125
12.50
0.42
300
30
147.64
14.76
0.49
226.38
22.64
0.75
3,500
350
11.67

Knowledge
Center

Skip to content